lab fittings company logolab fittings company logolab fittings company logolab fittings company logo
  • HOME
  • ABOUT US
    • FACTORY
    • CUSTOMERS
    • EXHIBITION
    • CERTIFICATES
    • EYEWASH INSTALLATION
    • .
      • Eyewsah Future Technologies
      • Company news
      • Industry news
      • Technical news
      • Laboratory Future technology
  • EYE WASH
    • Bench Eye Wash
    • Combination Shower & Eye Wash
    • Multi-function Eye Wash Station
    • Portable Eye Wash
    • Wall Mounted Eye Wash
    • Eye Wash Fittings
  • LAB FITTINGS
    • Lab Tap
    • PP Sink
    • Fume Extractor
    • PP Pegboard
    • Water Gas Valve
  • INSTRUCTION
    • ANSI/ISEA Z358.1-2014 
    • Test report
    • Related PDF Download
    • Video Collection
    • Safety Research & Compliance
  • CONTACT

Portable Eye Wash Instruction

  • Home
  • Technical news
  • Portable Eye Wash Instruction
What specifications should the eye wash & Showers equipment meet ?
March 26, 2018
Wall Mount Eye/Face Wash-WJH0358C
March 30, 2018

Portable Eye Wash Instruction

Categories
  • Technical news
Tags

Portable Eyewash (WJH0982)

Usage:

This product can be used in field of Petroleum, Chemical, Laboratory, Medical Treatment etc., and flushing the chemistry liquid sputtered eye and face rapidly, so reduce the level of injury to the minimum.

Main Performance:

Material: High density polyester, pro-environment and safety.

Capacity: The maximum reserve is 60L(16 gallon), workable is 40L availably, ensure flushing for 15 minute.

Water injection hole: wide water injection hole and apt to inject water, have dust cover.

Color: pro-environment green, aesthetic and striking.

Water flow: Due to change diameter on the water hole, so more bonhomie and rich, water yield is not lower than 1.5L/minute.

Installation:

Located near happen accident place, see easily and usage conveniently. Can install wall or bracket, or can use with go-cart, mounting height is installation schematic diagram; when open the eye wash arm, the sprayer should be 83.8cm~114.3cm above ground.

Using:

  1. After occur accident, must guide injured person to the nearest place of eyewash installation immediately, avoid long time to not wash;
  2. Pull down eye wash arm placidly, so open to spray ;
  3. When wash eyes, open eyes wholly, sufficient wash ,the wash time is not less than 15 minutes ;
  4. After wash, need medical treatment forward.

Maintenance:

  1. Portable Eyewash should be check periodically, look at water flow if minify and need water;
  2. Adopt preventive action to prevent water tank’s pollution, as follows: A: add suitable bacteriostat, after evacuate water and wash, then top up purified water, add defined amount bacteriostat;

B: if your choice washing fluid is purified water, should replace periodically (change period general is 5~7 days), every month must wash once at least( set drain valve, rotate the nut counterclockwise then drain water)

Attention:

  1. The best salve should safety protection preliminary, when you or your colleagues are proceed dangerous goods operation, please wear above equipments to make comprehensive defending: safety goggles, veil, protective gloves, chemical splash suit and so on.
  2. If eyes enter alkalinity or acidity solution, first should use corresponding eyewash ,then wash repetition by eyewash or medical assistance;
  3. On the working environment or environmental hazard, suggest add some measure of appropriative eyewash concentrate, can relief eyes harm, at the same time also lengthen liquid time .

Suggest install indoor ,the environmental temperature is 2degree ~35 degree

Trouble shooting:

Number

Problem

Reason

   Exclude measures

      1

1.No flow.

a.not water

b.water pipe or fitting clogging

 

1. a. Tank empty.Refill tank.

b.Obstruction in line or fitting.Clear obstruction.

     2

2.Poor flow from eyewash head(s).

a.water few

b.sprayer  clogging

2. a. Tighten head assembly.

b.Check for obstructions. If necessary, remove eyewash head(s), clean and reassemble. To reassemble head, place cap screw through head and thread into head anchor two or three turns. Tilt head assembly and work anchor legs into eyewash armholes. Tighten assembly. Check for leaks.

3

3.Water leak between joints or fittings.

 

rubber tube ageing

3.       a. Pull hose off fitting. Smooth raised plastic edge on center of fittings. Return hose and hose clamp to original position.

b. Tighten hose clamp(s) with pliers.

Share
admin
admin

Related posts

Heat-Traced Safety Stations

March 14, 2023

Is it better to heat the eyewash station or not to heat it? heat tracing Safety eyewash and Showers.


Read more
March 13, 2023

Lab Drying Rack Pegboard Bench-top – Wall-Mount- Cleaning Glassware


Read more
Lab Fume Exhaust

Lab Fume Exhaust

March 12, 2023

How to Choose the Right Lab Fume Exhaust?


Read more
March 8, 2023

What Kind Of Shower safety equipment Flushing Fluid Can Be Used?


Read more
February 27, 2023

Laboratory Extraction Arms,Flexible Arm,Fume Extractor Arm?


Read more
February 14, 2023

Emergency Combination Shower with Eyewash Station for hemical plant


Read more

Leave a Reply Cancel reply

You must be logged in to post a comment.

MENU

  • HOME
  • ABOUT US
    • FACTORY
    • CUSTOMERS
    • EXHIBITION
    • CERTIFICATES
    • EYEWASH INSTALLATION
    • .
      • Eyewsah Future Technologies
      • Company news
      • Industry news
      • Technical news
      • Laboratory Future technology
  • EYE WASH
    • Bench Eye Wash
    • Combination Shower & Eye Wash
    • Multi-function Eye Wash Station
    • Portable Eye Wash
    • Wall Mounted Eye Wash
    • Eye Wash Fittings
  • LAB FITTINGS
    • Lab Tap
    • PP Sink
    • Fume Extractor
    • PP Pegboard
    • Water Gas Valve
  • INSTRUCTION
    • ANSI/ISEA Z358.1-2014 
    • Test report
    • Related PDF Download
    • Video Collection
    • Safety Research & Compliance
  • CONTACT

TAGS

  • 0356A Polypropylene Sink
  • 2018 New Style PP Sink for Lab Use
  • 45 Degree Gas Nozzle
  • ABS Eye Wash
  • ANSI
  • ANSI Z358.1
  • ANSI Z358.1-2009
  • ANSI/ISEA Z358.1-2014
  • ANSI,ISEA ,Z358.1- 2014
  • assay faucet
  • bench eye wash
  • Bench lab Fume Exhaust
  • Bench-Top Eyewash
  • Bench-top Four-head Gas Cock
  • Bowl
  • Ceiling Mounted Exhaust Arm
  • Chemical industry
  • Chemical Safety
  • Combination Emergency Shower and Eye/Face Wash Unit
  • combination Emergency shower eye wash
  • Bench Eye Wash
  • Combination Shower & Eye Wash
  • Multi-function Eye Wash Station
  • Portable Eye Wash
  • Wall Mounted Eye Wash
  • Eye Wash Fittings
  • Lab Tap
  • PP Sink
  • Fume Extractor
  • PP Pegboard
  • Water Gas Valve
  • Lab Fittings
  • Other Products
    Contact
    Address: Industrial District,Wuqiang county ,Hebei province,China
    Tel: +86-318-3832252,+86-318-3832163
    Fax:+86-318-382 1299
    E-mail: rwd2016@163.com
Skype :cnchinawujie
Sitemap

Translation

EnglishالعربيةবাংলাFrançaisDeutschΕλληνικάBahasa IndonesiaItalianoBahasa MelayuپارسیPortuguêsРусскийSlovenčinaEspañolSvenskaภาษาไทยTiếng Việt

RunWangDa company

Is a professional enterprise concentrating on R&D, manufacture of modern laboratory fittings and eyewash.As the first manufacturer of domestic laboratory accessories, our main products include : Eye wash (Station),Emergency Shower, laboratory faucets for water and gas, fume exhaust, peg board, PP sink, emergency shower ,etc.We only produce the best quality eye wash and Laboratory Service Fittings! Classic Version
Runwangda for your Safety, Lab and Science Laboratory

LAST UPDATE

  • heat tracing Safety eyewash and Showers Drawing PDF
    March 14, 2023
  • Is it better to heat the eyewash station or not to heat it? heat tracing Safety eyewash and Showers.
    March 14, 2023
  • Lab Drying Rack Pegboard Bench-top – Wall-Mount- Cleaning Glassware
    March 13, 2023
© 2017 Hebei Runwangda Making Clean Materials Co., Ltd. All Rights Reserved.